Humidity

Browse our sub categories

  • Humidity

Humidity Measurement

The main fields of use for humidity measuring equipment lie in the air-conditioning (HVAC) and food industries, heating, ventilation, pharmaceutical  and applications as well as drying processes and storage. Measurement of air humidity moreover plays a key role in meteorology, while archives and museums also use data loggers or humidity measuring instruments. Apart from humidity, temperature is often also measured. Rotronic humidity measuring instruments therefore usually also measure temperature at the same time.

Status Instruments provide a range of “smart” humidity transmitter with either 1 or 2 x (4 to 20) mA two wire outputs. The products will measure humidity, temperature, dew point and delta T (the difference between dewpoint and ambient temperature) values. Using free software,  PC configuration allows you to output any of these 4 parameters onto the 4 to 20mA signal. 

Configuration is performed quickly using our new USB port driven configurator by connecting the transmitter to the configurator and following the software instructions. The software allows you to tag the device, set installation date and set output range. Either fixed ranges or your own custom ranges can be configured for all output types in °C or °F.

The 4 digit LED display option provides you with a visual indication of the process parameters, the display may be set to indicate either humidity, temperature, dew point or toggle between all three parameters.

View Product

Status SEM160i

Low-Cost Humidity transmitter
  • Humidity, Temperature Measurement
  • (4 to 20) mA Loop-Powered Output
  • duct and Wall Mount Versions
  • Switch to select pre-stored configuration on dual-channel version
  • Direct temperature sensor measurement in ohms (Standard Thermistor Optional Pt100)
  • Single and Dual Channel Versions

The lower cost humidity and temperature transmitter SEM160i is a single/dual channel RH and temperature transmitter for industrial and BMS/HVAC applications. The unit can be supplied in single or dual-channel ( two-wire (4 to 20) mA ) versions, the single-channel version has a thermistor (optional Pt100) mounted in the sensor tip for direct temperature sensing by users.

View Product

Status DM650HM

Humidity & Temperature Gauge With Data Logging, Alarm & Messaging
  • %rh, temperature, dew point, delta t
  • Alarm relay/user set display messaging
  • USB and NFC interface
  • Battery-powered
  • 5000 point data logger

The DM650HM humidity gauge has been designed to display % relative humidity, temperature, dew point and delta temperature, on a 6- digit LCD display. The instrument offers an advanced display mode, allowing the user to display not only process variables but one or two (1 – 32) character messages. This feature is further enhanced by the ability to split a process range into eight user-set bands, each band having independent user-selected messages. The DM650HM also has a changeover-type relay with multiple programmable options allowing the user to set a high, low or deviation alarm.  Wall and duct-mounted versions are available.

Learn about humidity sensing here

DATA LOGGING FUNCTION
DM650HM humidity gauge also provides a powerful data-logging function. The log points can be set up to 5000 points, each
point is time and date stamped together with %RH, temperature and relay-state information.
Two methods of reading the log are available. The USB configuration reads the log and allows the user to
save to a text file. The NFC android interface allows data transfer to compatible android phones or
tablets; by using the downloadable App.

View Product

Delta Ohm HD2301

The HD2301.0 is a portable humidity meter with a LCD display.

It measures relative humidity and temperature using combined temperature and humidity probes. Temperature only is measured by immersion, penetration, air or contact probes. The sensor can be a Pt100 or Pt1000. When the humidity/temperature combined probe is connected, the instrument calculates and displays the absolute humidity, the dew point, the partial vapour pressure.

The probes are fitted with an automatic detection module, with the factory calibration data already stored inside.

The Max, Min and Avg function calculate the maximum, minimum, and average values. Other Functions: REL, HOLD and auto power off which can be disabled. The instruments have IP67 protection degree.

View Product

Alpha Moisture SADPmini2

The SADPmini2 is the next generation of Hand Held Dewpoint Meters

Introducing the latest development in portable moisture measurement, the SADPmini2 Hand Held Dewpoint Meter Range, from Alpha Moisture Systems. The SADPmini2 is the industry's latest addition for measuring moisture content, or dewpoint in gases and dry compressed air.

This latest technology, functionality and software ensures ease and speed of use for rapid spot checks of moisture in gases. With various ranges available between -120ºC to +20ºC (-184ºF to +68ºF) dewpoint, the SADPmini2 is the most versatile portable hand held dewpoint hygrometer available for rapid spot checks of trace moisture content, or dewpoint, in most gases.

View Product

Alpha Moisture Model DS1200

Model DS1200 - Single Channel Analyser

Model DS1200 from Alpha Moisture Systems is a single channel on-line hygrometer designed to measure dewpoint in process gases and dry compressed air. The panel mounted ? DIN dewpoint meter, providing panel protection to IP65 (NEMA4X), combines with the Model AMT range of ultra high capacitance sensors for accurate trace moisture measurement.

Combination of advanced digital technology of the display electronics and the sensor, makes this the system of choice for a wide range of applications where precise indication, control and monitoring is critical.

Model DS1200-AMT system can be factory configured to read in °C dewpoint, °F dewpoint, ppm(v), ppb(v), g/m³ or lbs/MMSCF. The measured value is displayed on a large 4 digit, 13.8mm high, fourteen segment LED display.

The instrument offers two fully programmable alarm relays, which can be independently set across the full operating range of the sensor. An optically isolated analogue signal, linear with the measured unit, is also available to interface with any external device.

View Product