Isolators, Converters, Splitters

Browse our sub categories

  • Isolators, Converters, Splitters

STATUS Isolators, Splitters, Converters

Status Instruments offer a range of Powered Signal Conditioners, Trip Amplifiers, Splitter & Calculators:

  • mA or Voltage output for Pt100, T/C or Potentiometer Sensors
  • Frequency / Pulse Sensors and provides mA or volt output
  • 3-Wire Voltage Output For Pt100, Thermocouple and Passive mA Signals
  • 2-Relay output for Pt100 / Potentiometer Sensors
  • Universal Input With Dual Relay and Process Output Signal
  • 2-Channel mA/voltage on input and output. Maths functions also
  • Provides mA or voltage input/output with linearisation option
  • Load cell sensors. Provides mA or voltage output
  • 2-Relay output for Pt100, Thermocouple Sensors and mV, mA signals
  • Loop powered trip amplifier with 2 relay outputs
  • 2-Channel for Pt100, T/C. mA or volt output. Maths functions also
View Product

Status SEM1000

4 to 20 mA Ground Loop Isolator
Ground loop isolator
Output powered from the input loop
High accuracy
Galvanic isolation
High reliability

The SEM1000 ground loop isolator is designed to be series connected into a new or existing (4 to 20) mA current loop

and provide an isolated (4 to 20) mA signal capable of driving into 300 Ω maximum load. The output is powered from the input loop.
This ground loop isolator requires no user adjustment during commissioning. Minor adjustments can be made to the calibration of the device by means of the two front panel accessible calibration potentiometers.
Incorrect connection in the loop will not damage the device as long as the specified maximum currents/voltages are not exceeded.

View Product

Status SEM1015

Loop Powered Voltage to Current convertor / Isolator
Accepts any DC voltage input between -10 and 100 vdc
Loop-powered 4-20mA output
Can be used as adder or subtractor
High accuracy
Galvanic isolation

This loop-powered voltage isolator can be configured to accept most of the common voltage ranges found in both commercial and industrial applications between the range. The input is fully isolated from the output circuit. The loop-powered voltage isolator range can be specified at the time of order, but if required the user may re-range the transmitter to a new range. The Isolator is housed inside a plastic enclosure, suitable for DIN rail mounting. Screwterminals are provided for wire connections. The enclosure provides side entry access to coarse offset and span adjusters and a range selector switch.

View Product

Status SEM1020 MKII

4 to 20mA Loop Booster
Provides extra drive capability from an existing current loop
Only required 2.7v from the existing loop
Galvanic isolation
High accuracy

The SEM1020 current loop booster is designed for use when power is available at both sides of the isolation barrier (joining two powered loops together) and hence adds additional load capacity to an existing loop.
This isolator requires no user adjustment during commissioning, apart from an initial test, to ensure it operates correctly over its full working range.

HIGH ACCURACY
Only ± 10 uA error between the input and output signals ensures confidence in the SEM1020 products performance.

View Product

Status SEM1022

4 to 20mA Loop Booster
Provides extra drive capability from an existing current loop
Dual-channel
Only required 2.7v from the existing loop
Galvanic isolation
High accuracy

The SEM1022 4 to20mA loop isolator is designed for use when power is available at both sides of the isolation barrier and has two independent channels in the same housing.
This isolator requires no user adjustment during commissioning, apart from an initial test to ensure it operates correctly over its full working range. Minor adjustments can be made to the calibration of the device by means of the front-panel accessible calibration potentiometers.
Incorrect connection in the loop will not damage the device as long as the specified maximum currents/voltages are not exceeded.

HIGH ACCURACY
Only ± 10 uA error between the input and output signals ensures confidence in the performance of the SEM1020 product.

GALVANIC ISOLATION
With 500vdc isolation between input and output circuits, the SEM1020 is an ideal solution for removing ground loops between (4 to 20) mA loop equipment.

JOINS POWERED INPUT AND OUTPUT (4 to 20) mA LOOPS
The SEM1022 current loop booster requires powered loop supplies on both input and output connections, enabling it to safely join two active supplies where there is a conflict with more than one piece of equipment powering a control loop.

BOOST A (4 to 20) mA LOOP
The loop isolator can be used to extend the range of a weak (4 to 20) mA control loop by allowing an additional loop power supply to be added, isolated from the primary loop supply.

LOOP TRIM FUNCTION
The SEM1022 can be used to add a (4 and 20) mA fine trim function to a sensor with no trim options.


View Product

Status SEM1200 MKII

Passive (4 to 20)mA Loop Splitter
Provides 2 isolated 4-20mA outputs from 1 4-20mA input
High accuracy
Galvanic isolation
12.5mm wide

The SEM 1200 is a current loop splitter and isolator, providing two separate isolated (4 to 20) mA current signals from a primary loop. The output loops must be powered externally. This current loop splitter requires no user adjustment during commissioning, apart from an initial test, to ensure it operates correctly over its full working range. Minor adjustments can be made to the calibration of the device by means of the two front panel accessible calibration potentiometers. Incorrect connection in the loop will not damage the device as long as the specified maximum currents/voltages are not exceeded.

View Product

Status SEM1300 MKII

HIGH-PERFORMANCE DIN RAIL POWER SUPPLY
100-240VAC supply voltage
24VDC @ 0.5A output
UL approved

The SEM1300 MKII is a high-performance switch mode power supply that is 17.5mm wide and which complements our range of DIN rail transmitters It connects to 100 to 240 VAC and provides an isolated 24 VDC supply @ 0.5A

View Product

Status SEM1600B

For load cell sensors. Provides mA or voltage output
Accepts up to 4 load cells in parallel
Output current or voltage signal
Calibration function
Remote Tare function
Power supply 10-32VAC or 10-48VDC supply
View live data on an Android phone or tablet

The loadcell amplifier SEM1600/B is a “smart” powered bridge loadcell amplifier for use with load cell signals. The product has a built in capability to scale the input signal to a process value while the output stage offers either voltage, bipolar voltage or active / passive current re-transmission signals.

The product comes with an AC/DC power supply that will operate in the range (10 to 48) V DC and (10 to 32) V AC making the device ideal for battery operation. An additional volt-free contact input is available for tare setting using a remote switch. The high precision input stage of the device allows for a bridge excitation voltage of 5V DC to be used as opposed to the traditional 10V DC. This reduces the power requirement for the bridge supply and up to four bridges (cells) may be connected to the input.

Read more about load cells here

View Product

Status SEM1600F

Frequency / Pulse conditioner for flow or counting applications

Dual or single universal frequency inputs sensor excitation
Frequency (0.1 to 65000) Hz counter (DC TO 1000) hZ)
Rate, totalise, k factor, m factor, maths
Relay output
mA, voltage, bipolar voltage output
View live data on an Android phone or tablet

This signal conditioner accepts frequency and pulse sensor outputs with a frequency range between (0.1 to 65000) Hz in standard configuration and (DC to 1000) Hz in counter mode. Typical applications would be to measure flow or batch counting.

The product has a built-in capability to operate as a dual input which allows differential flow/count measurement with advanced maths functions. Or as a single channel input, with an external reset contact.

When operated in signal channel mode, the discrete input can be programmed to reset the total counter, batch counter or latched relay. The input can also be programmed to control the total counter direction with a combination of count-up, count-down or halt modes available.

THREE OPERATING MODES

  • Basic frequency mode to process signal mode, analogue + relay outputs.
  • Advanced frequency mode with K factor, M factor, totalize, rate, maths functions, process signal, 12-point user linearisation for channel A using meter correction, analogue + relay outputs.
  • Pulse counter mode with K factor, totalize, maths functions, process signal, analogue + relay outputs.

USB CONFIGURATION The product uses a built-in USB port for configuration, together with a simple to use, free menu-driven software configuration tool, allowing the user to take advantage of the products’ comprehensive specification.

ANALOGUE OUTPUT The output stage offers either voltage, bipolar voltage or active/passive current re-transmission signals. The output signal can be ranged to a scale anywhere within the process range.

RELAY OUTPUT A volt-free output contact is provided capable of operating as either a trip relay, latched relay or pulsed relay. High and low-level relay functions are also available. Trip options on rate, count, totalize or maths functions.

SIGNAL RETRANSMISSION SCALING The input signal range for retransmission can be selected from any part of the maximum input capability. The output signal range can be selected from any part of the total output capability, for example (0 to 12) litres per minute input to (1 to 5) mA output.


View Product

Status SEM1600T

Temperature or Potentiometer input with mA or voltage output

Accepts RTD, Thermocouple or Slidewire Sensors
Current (Active or Passive), Voltage Or Bipolar Voltage Output
Powered ( 10 to 32) V AC / (10 to 48) V DC Supply
22 Segment User Linearisation
Sensor Offset and Output Alignment
View live data on an Android phone or tablet

Signal conditioner for temperature probes as well as potentiometer sensors. The SEM1600T accepts signals from RTD, Potentiometer or Thermocouple sensors. Other sensor characteristics, or your own 22 point linearisation characteristic (for potentiometers, linear resistance or mV sensors) can be downloaded into the product enabling you to adapt it exactly to your application.

The output stage offers either voltage, bipolar voltage or current re-transmission signals.

For ease of use, the signal conditioner for temperature and potentiometer sensors offers a high-efficiency switch-mode power supply is fitted as standard and does not require any adjustment between ac or dc applications. Operating voltages are (10 to 48) V dc and (10 to 32) V ac.

View Product

SEM1600VI

mA or voltage input with isolated mA or voltage output

Accepts Internal and External Powered Current Loops On Input and Output
+/- 50V DC or 50 mA input
Current, Voltage Or Bipolar Voltage Output
Powered (10 to 32) V AC / (10 to 48) V DC Supply
22 Segment User Linearisation
View live data on an Android phone or tablet

Process input signal conditioner. The SEM1600VI is a “smart” powered isolator/conditioner that accepts any voltage signal between (-50 and 50) V dc or any current signal between (-50 and 50) mA. The output stage offers either voltage, bipolar voltage or current re-transmission signals.

For ease of use, a high efficiency switch mode power supply is fitted as standard and does not require any adjustment between ac or dc applications. Operating voltages are (10 to 48) V dc and (10 to 32) V ac.

View Product

Status SEM1620

Universal input and 3 wire voltage output

Pt100,Thermocouple,mV,mA Input
(0 to 10), (0 to 5), (2 to 10), (1 to 5) and ( 0 to 1)V DC Programmable output
Push Button User Trim For In-Process Fine Tuning
Galvanic isolation
View live data on an Android phone or tablet

Temperature signal conditioner. Provides 3 Wire Voltage Output. The SEM1620 signal conditioner provides a 3 wire isolated voltage output signal and accepts RTD, Thermocouple, mV and passive current sensor inputs. It has been designed to accept most common process and temperature sensor inputs and provide the user with a three-wire voltage output signal. Isolation is provided between input and output and all temperature ranges are linear to temperature.

Designed for ease of use, the temperature signal conditioner has a direct USB interface is fitted for quick and easy configuration. Just connect a standard USB cable between the SEM1620 and your PC and you’re ready to go. Using our free configuration software, your PC will automatically read the current configuration data and guide you through any changes you wish to make.

View Product

Status SEM1630

Universal input with 2 relay outputs

Pt100, Thermocouple, mA, mV input
Dual Relay Outputs 250V AC @ 1A
Relay Contacts isolated from each other
Galvanic isolation
View live data on an Android phone or tablet

Universal trip amplifier SEM1630, provides a dual relay switch function for RTD or Thermocouple sensors as well as mA and mV signals. Its relays can be programmed to be either high or low alarms.

Designed for ease of use, the universal trip amplifier uses a USB port for quick and easy configuration. Just connect a standard USB cable between the product and your PC and you’re ready to go. Using our free configuration software, your PC will automatically read the current configuration data and guide you through any changes you wish to make. To further help save time, the SEM1630 range does not need to be wired to a power supply during the configuration process, it is powered via the USB interface from your PC.

View Product

Status SEM1636

Loop powered with 2 relay outputs

Dual Change Over Relay Output
Relay Rating 250V AC 1A; 30V DC 1A
Latching Relays In Case Of Loop Failure
Powered From 4/20mA Loop
LED Alarm Indication
View live data on an Android phone or tablet

Loop-powered trip amplifier. The SEM1636 monitors a (4 to 20) mA loop and provides two independent change over trip contacts set to trip at any point within the (4 to 20) mA range. The SEM1636 requires no additional power connection as power is derived from the (4 to 20) mA loop. Trip outputs are independently configured for action and setpoint, dead band. Six actions are provided normal High/Low/Deviation and inverted High/Low/Deviation. Additional math filter and user linearization functions are provided.

Designed for ease of use, our latest USB interface is fitted for quick and easy configuration.

Just connect a standard USB cable between the loop-powered trip amplifier and your PC. Using our free configuration software, the user can configure the device to the required application. To further help save time, the SEM1636 does not need to be wired to a power supply during the configuration process, it is powered via the USB interface from your PC.

View Product

Status SEM1700

Universal Input With Dual Relay and Process Output Signal

RTD, Thermocouple, mV, V, mA and Potentiometer Input
Isolated Universal Voltage or Current Output
Dual C/O Relay Trip Outputs
Universal Power Requirement 22 to 250V AC or DC
Powers both input and output current loops
SIL Approved
View live data on an Android phone or tablet

Universal signal conditioner, the SEM1700 is a DIN rail mounted and accepts RTD, Thermocouple, Voltage, Current and Potentiometer sensor inputs and provides the user with a programmable current or voltage output signal plus dual trip relays. Isolation is provided between input, outputs and supply. All temperature ranges are linear to temperature. Both input and output loop excitation is provided as well as a fully universal power supply.

Designed for ease of use, the universal signal conditioner has a USB interface fitted for quick and easy configuration. Just connect a standard USB cable between the SEM1700 and your PC. Using our free configuration software, your PC will automatically upload the existing configuration data and guide you through any changes you wish to make. To further help save time, the SEM1700 does not need to be wired to a power supply during the configuration process, it is powered via the USB interface from your PC.

View Product

Status SEM1720

2 Channel for Pt100, T/C. mA or volt output. Maths functions also

Dual-Channel With 5 Port Isolation (3.75Kv)
Accepts RTD, Thermocouple or Potentiometer Sensors
Maths Functions Between Channels
Sensor Redundancy Switching
Eight User-Configured Preset Configurations

Temperature measurement signal conditioner.   SEM1720 is a dual-channel signal conditioner designed to accept RTD, Thermocouple, or Potentiometer sensors and provide isolated, industrial process output signals in mA or Volts. Each output channel may be linked to either an input sensor or to a maths function of both sensor signals. This powerful feature allows the device to operate in several different modes.

The output signal can also be adjusted over the full working ranges (0 to 20) mA or (0 to 10) V, to provide common or custom process signals, examples (4 to 20) mA, (0 to 1) mA, (1 to 5) V.
The temperature measurement signal conditioner, SEM1720, is configured using free software that allows the user to configure the device without requiring calibration equipment. Maths functions on each channel can be set up using the software as well as a 22-segment profile tool. Input/output simulation tools for diagnostic purposes are also available.

FEATURE HIGHLIGHT

  • 2 Channel RTD, Thermocouple or Potentiometer Inputs
  • 2 x Outputs can be either isolated current or voltage straight through from the sensor
  • Configure as a signal splitter active or passive
  • Average or difference of the 2 input sensors can be programmed
  • Sensor fail-safe.
View Product

Status SEM1750

2 Channel mA / voltage on input and output (Maths functions also)

Dual Channel Voltage Or Current (Active/Passive)Inputs and Outputs
5 Port Isolation To 3.75Kv
Can be Configured As An Active Signal Splitter
User-selectable Maths Functions on each output channel
Signal linearisation
Signal Simulate function for diagnostics

Process signal conditioner, SEM1750, is a dual-channel signal conditioner designed to accept mA or voltage inputs and provide isolated, industrial process output signals in mA or Volts. Each output channel may be linked to either an input signal or to a maths function of both input signals. This powerful feature allows the device to operate in several different modes.

The output signal can also be adjusted over the full working ranges (0 to 20) mA or (0 to 10) V, to provide common or custom process signals, examples (4 to 20) mA, (0 to 1) mA, (1 to 5) V.
The process signal conditioner is configured using free software that allows the user to configure the device without requiring calibration equipment. Maths functions on each channel can be set up using the software as well as a 22-segment profile tool. Input / output simulation tools for diagnostic purposes are also available.

FLEXIBLE
The SEM1750 has a wide range of process input options (-50 to 50) mA, (-50 to 50) V.
With comparison functions between channels, paired with the configuration functionality it has to offer, it is a flexible and versatile tool for many varied process applications. Live readings can be displayed to a PC via the configuration software.

View Product